Datasheet
 MONITOR 
Below functions are available: 
Measurement mode 
Screen type 
Form of measuring results 
Monitor 
Vrms 
Display specifications like voltage, harmonics, flicker, 
swells, dips, voltage rapid change, interruption, 
unbalance, frequency etc. of power quality parameters 
Bar graph 
Detailed bar graph of harmonics 
Trend 
Trends of selected data set over time 
Events table 
Record events violate limit 
5.5 Screen and Function Keys 
The Analyzer uses five different screen types to present measuring results in the most effective way.  
 Table screen 
Picture: Table screen 
This screen gives an instantaneous overview of important numerical measuring values. Such as Table 
screen under VOLTS/AMPS/HERTZ mode. 
Screen information: 
(1)  The screen header shows current measurement mode. 
(2)  Status indicator and status line. 
(3)  Measurement parameters and values. The content depends on the measurement mode, phase 
number and wiring configuration. 
Function keys: 
F1 
For 3-phase Y type wiring configuration, switch between phase voltage and line voltage. 
F4 
Access to the Trend screen. 
F5 
Switch between RUN and HOLD. 
-45- 