User Manual
130
5.24 Firmware Version Code
Firmware code of ‘1694B.00’ will display in the interface once power on. It will be available once
maintain, which can be set and modified.
Press 【Utility】key and then〖 System〗softkey to check the firmware number and factory series
number.
5.25 Default Setting
5.25.1 Continuous Output
Waveform Sine Duty Cycle of Square
50%
Frequency 1kHz Symmetry of Ramp
50%
Amplitude 1Vpp Pulse Width 200µs
DC Offset 0Vdc High Level Limitation 10Vdc
Output Phase 0° Low Level Limitation -10Vdc
Output Polarity Normal Frequency Step 25Hz
Amplitude Range Auto Amplitude Step 25mVpp
External Load High Z Output Port Off
5.25.2 Modulation Output (FM, AM, PM, PWM and Sum)
Frequency Difference 100Hz Sum Frequency 20kHz
AM Depth
100%
Modulating
Frequency
10Hz
Phase Difference 90° Modulating
Waveform
Sine
Pulse Width Difference
50%
Modulating Source Internal
Sum Amplitude
20%
Modulating State Off
5.25.3 Modulating Output (FSK and BPSK)
Hop Frequency 100Hz Modulating Source Internal
Hop Phase 180° Modulating State Off
Hop Rate 10Hz