4.10.6. Signal output port:
* Output】:the signals that the instrument generates are all output from the signal output port, press
Outputkey to open or close the signal from the output port circularly.
* The output port is open when the “Output” light is on, and close when the Output” is off. If wrongly
connect external high voltage to signal output port, instrument will suffer “inverse filling” danger, and then
instrument will turn on the protection function, close immediately signal output port and make an alarm
with the “Output”light off. In this case, you must check external load, only after eliminating the failure can
pressoutputkey to open signal output port.
4.10.7. Sync output portSync:
Output pulse wave compatible with TTL and CMOS, high level4 Vlow level 0.3 V.
1.) Under single frequency function, sync signal is a square signal with TTL level, the frequency of sync
signal is the same as the frequency of the signal fromOutputportwhen the phase is set to be
0the phase of sync signal is the same as the phase of the signal from the Outputport. When the
phase is set to be 1the phase of sync signal is the opposite of the phase of the signal from the
Outputport.
2.) Under frequency sweep function, the sync signal is a pulse signal with TTL level, the rising edge of
the pulse wave match along with the start point of the sweep, and the falling edge of the pulse wave
match along with the middle point of sweep range, the period of pulse wave is the same as sweep
time.
3.) In FM, AM, PM, PWM modulation, sync signal is a square wave with 50% duty cycle, whose
frequency equals to frequency of modulating waveform and phase refers to the phase of modulating
waveform.
4.) In FSK, sync signal is a square wave with 50% duty cycle, whose frequency equals to hop rate, when
outputting carrier frequency, sync signal is low level; when outputting hop frequency, sync signal is
high level.
5.) When pulse string output, sync signal is a pulse wave whose rising edge corresponds to start point,
falling edge corresponds to stop point, and cycle equals to pulse string repeated cycle.
6.) In frequency sweep, pulse string and FSK, if select manual trigger or external trigger, frequency of
sync signal will be determined by trigger signal.
4.11. Input port
There is a trigger input portTrig Inon the rear panel of the generator, which could be used only as the
input channel of external signal, but not output channel. This port could be also used as the input channel of
pulse signal which is compatible with TTL and CMOS, the high level of which is higher than 4V, and low level
is lower than 0.3V.
4.12. Programmable interface
* There is an USB device interface socket USB Device on the rear panel of the instrument, through
which the instrument could be program-controlled by connecting to computer with an USB cable. The use
method of this interface is described in detail in the CD that attached with the instrument.
4.13. Parameter calibration
* The instrument is calibrated before shipment, but some specifications may change a bit lot during long
time of use. To ensure the accuracy, the instrument should be calibrated termly.
* Users may regain the accuracy of the instrument by operating the keyboard to calibrate the main
specifications without removing the cover of the instrument.