Datasheet

14
You also can generate signal burst (still with 5 cycles) by selecting Manual Trig under
pressing Source Int/Extsoftkey. Then each time you press Manual Trigsoftkey, one
five-cycle burst will be output. Press number depends on the desired burst number.
4.3.12 Frequency Coupling
If you want to couple frequencies between the two channels,
1. Press Dual Channelkey. The dual channel menu is shown in the current screen.
2. Press the Freq Cplsoftkey to turn frequency coupling on. Then press More
softkey to configure frequency coupling.
3. Press Continuous key to configure CHA frequency, just because channel
frequencies can be linked with a constant ratio or difference between them, CHB
frequency will be changing as CHA changes.
4.3.13 Frequency Counter
If you want to measure a frequency of external signal,
1. Press Counterkey to enter into Counter mode and display the counter menu and
count results.
2. Input measured signal through ‘Counter’ connector at rear panel.
3. Press Meas Typesoftkey, the generator begin to measure then display the
measured frequency value.
4. For Square input, press Duty cycsoftkey to enable the duty cycle measurement
and display the duty cycle.