Datasheet

24.9.2019 PeakTech® 4046 - PeakTech® - Convincing Top Technology
https://www.peaktech.de/productdetail/kategorie/dds-funktion-arbitrary-generator/produkt/peaktech-4046.html 2/3
FREQUENCY RANGE :
Sine 1 μHz - 160 MHz
Square & Pulse 1 μHz - 50 MHz
Arbitrary 1 μHz - 30 MHz
Ramp 1 μHz - 5 MHz
Frequency Resolution 1 μHz; 12-digits
Accuracy ±2 ppm+1 μHz
WAVEFORM :
Standard Waveforms Sine, Square, Rampe, Pulse, Noise, DC
Arbitrary Waveforms 137 Integrated Waveforms
SINE WAVEFORM :
Harmonic Distortion (Sine) ≤ -60 dBc (< 10 MHz); ≤-45 dBc (≥100 MHz)
Total Distortion (Sine) ≤ 0.1% (20 Hz … 20 kHz, 20 Vpp)
SQUARE, PULSE AND RAMP :
Edge-Time (Square) ≤ 8ns
Duty Cycle (Square) 0.1% - 99.9%
Pulse Width 10 ns ~ 1000 s
Symmetry (Ramp) 0.0% ~ 100.0%
ARBITRARY WAVEFORM :
Arbitrary Waveform Length 6 - 1M Points
Arbitrary Sampling Rate 500 MSa/s
Vertical Resolution 14 bits
AMPLITUDE SPECIFICATION :
Amplitude Range 2 mVpp ~ 20 Vpp (≤ 40 MHz) … 2 mVpp ~ 4 Vpp (≥120 MHz)
Accuracy ±(setting value x1%2 mVpp)
Amplitude Resolution 0.1 mVpp - 2 mVpp
MODULATION OUTPUT (CHA & CHB) :
Modulation Frequency 1 mHz … 100 kHz
Modulation Depth 0% - 120%
Phase Deviation 0° - 360°
FSK, 3FSK, 4FSK Hop Frequency 1 μHz … Max. Frequency @ 1 mHz...1 MHz Hop Rate
SWEEP (CHA & CHB) :
Sweep Time 1 ms … 500 s
Sweep Type Linearity, Logarithm
BURST MODE :
Waveform Sine, Square, Sawtooth…
Period 1 μs - 500 s @ 1 - 1000000
Start-End Phase 0° - 360°
Trigger Source Internal, External, Manual
CHANNEL COUPLING :
Frequency Coupling Freq. Ratio, Difference
Amplitude Coupling Amp. Difference, Offset Difference
FREQUENCY COUNTER :
Measurement Range 0.1 Hz - 350 MHz
Resolution 7 Digits