Datasheet

-68-
8 Technical Specifications
8.1 Thermal Imager
Field of view (FOV) / Minimum focus distance
21° x 21°/ 0.5m
Spatial resolution (IFOV)
4.53mrad
IR resolution
80
×
80 pixels
Thermal sensitivity/NETD
<
0.1°C @ +30°C (+86°F) / 100 mK
Image frequency
50Hz
Focus mode
Focus free
Focal length
7.5mm
Focal Plane Array (FPA)/Spectral range
Uncooled microbolometer / 814 µm
Object temperature range
20°C to +260°C (4°F to +500°F)
Accuracy
±3°C (±5.4°F) or ±3% of reading (Environment temperature
10
-35°C, object temperature >0°C. )
Accuracy calculated as [%reading
+
(num. digits*resolution)] at 18°C ÷ 28°C <75%HR
DC Voltage
Range
Resolution
Accuracy
Input impedance
Protection against overcharge
600.0mV
0.1mV
±(0.09%reading + 5digits)
>10MΩ
1000VDC/ACrms
6.000V
0.001V
60.00V
0.01V
600.0V
0.1V
±(0.2%reading + 5digits)
1000V
1V
AC TRMS Voltage
Range
Resolution
Accuracy
(*)
Protection against overcharge
(50Hz÷60Hz)
(61Hz÷1kHz)
6.000V
0.001V
±
(
0.8%
r
e
a
d
i
n
g
+
5
d
i
g
i
ts)
±
(
2.4%
r
e
a
d
i
n
g
+
5
d
gt
)
1000VDC/ACrms
60.00V
0.01V
600.0V
0.1V
1000V
1V
(*) Accuracy specified from 10% to 100% of the measuring range,
sine wave.
Input impedance: >9MΩ;
Accuracy PEAK function: ±10%rdg, PEAK response time: 1ms
AC+ DC TRMS Voltage
Range
Resolution
Accuracy (50Hz÷1kHz)
Input impedance
Protection against overcharge
6.000V
0.001V
±(2.4%reading +20dgt)
>10MΩ
1000VDC/ACrms
60.00V
0.01V
600.0V
0.1V
1000V
1V