Datasheet

8.Technical Data
8.1. Specifications
Display
TFT-LCD-display with max display of
59999
Overload protection
on all ranges
Operating Temperature
5°C to 40°C < 80 % RH
Storage Temperature
-20...+60° C < 80 % RH
Altitude
< 2000 m
Accuracy temperature
18°C…28°C (64°F to 82°F) to
maintain guaranteed accuracy
8.2. General Specifications
Enclosure
Double molded, waterproof
Shock (Drop Test)
6.5 feet (2 meters)
Diode Test
Test current of 0.9mA maximum,
open circuit voltage 2.8V DC typical
Continuity Check
Audible signal will sound if the
resistance is less than 30 , test
current <0.35mA
PEAK
Captures peaks >1ms
Temperature Sensor
Requires type K thermocouple
Input Impedance
>10M VDC
AC Response
True RMS
ACV Bandwidth
50Hz ~ 5000Hz
Overrange indication
“OL.” is displayed
Auto Power Off
approx 15 min
Polarity
Automatic (no indication for
positive); Minus (-) sign for negative
Measurement Rate
3 times per second, nominal
Interface (P 3442 only)
Bluetooth 4.0 Low Energy
-74-