User Manual

1. Switch back and forth from Auto or Manual scanning mode
bay pressing the Auto/Manual button on the side of the
master-testing unit.
2. Once both ends of the cable are plugged in properly, the
second row of LEDs will illuminate according to the
corresponding LEDs in the top row.
3. Read the results of the LED display for the pin configuration
status of the tested cable. If you fail to read the results the
first time in Auto mode, you may wait for the second LED
scan, or simply switch to manual mode for the pin by pin will
advance testing to the next pin.
RJ-11 Modular Cable test
Please follow directions for the UTP/STP cable Test and use the
operations manual for the correct LED pin out display.
Coaxial Cable Test
1. Plug the two attached BNC adapter cables on both RJ-45
jacks. Then connect the tested cable to each end of the BNC
adapter cables.
2. For the remaining testing procedure, please refer to 10Base-
T Test steps 2 to 5.
Note:
1. The centre pin of BNC should be read on LED 2.
2. As coaxial cable has only two wires, we suggest you read
the result of the LED scan using manual mode.
-42-