User Manual

9. Test switch for manual scan
10. Function switch
11. 3 ½ digit (2000 count) LCD display for DMM functions
12. MODE button
13. MAX Hold button
14. Data Hold button
15. COM input jack
16. V, , µA, mA input jack
17. Batter Cover
3.3. DC Voltage
Range
Accuracy
Resolution
200 mV
± 0.5 % + 3 digit
100 µV
2 V
± 1,0 % + 3 digit
1 mV
20 V 10 mV
200 V 100 mV
600 V 1 V
Input Impedance: 7,5 M on all ranges
Overload protection: 600 V DC or peak AC
rms
on all
ranges
3.4. AC Voltage
Range
Accuracy
Resolution
2 V ± 1.0 % + 5 digit 1 mV
20 V 10 mV
200 V ± 1,5 % + 10 digit 100 mV
600 V 1 V
Input Impedance: 7,5 M on all ranges
Frequency range: 50 Hz/60 Hz
Overload protection: 600 V DC or AC
rms
in all ranges
Indication: Average (rms of sine wave)
-30-