User Manual

5. H/MAX Switch
This switch has two modes, one is data hold the other is
maximum hold. Sliding the function switch to power on, this
switch will work in data hold mode. Pressing the H/MAX switch
then slide the function switch from power off to power on, this
switch will work in maximum hold mode.
Data Hold mode
This mode is used to hold measured value for all functions,
push this switch then HOLD annunciator is displayed.
Conversions are made but the display is not updated.
Maximum Hold mode
This mode is used to hold the maximum measured value for all
functions except continuity mode. Press this switch the “MAX”
annunciator turns on then enters the maximum hold mode.
Press this switch again to restart recording. Press this switch
more than 2 seconds to exit the maximum hold mode.
6 Zero Switch
This switch is used to zero the reading on display. It work in DC
and AC current function only. In zero mode, the reading maybe
exceed ± 4000 counts.
7. /AC/DC Selection switch
Push this switch alternately to measure AC voltage or DC
voltage in the V ~ function or to measure AC current or DC
current in the A ~ function. or to measure resistor or continuity
in /function. Auto power disable mode - press this switch until
slide the function switch power on for 1 second it will cause the
auto power off function disable.
8. Trigger
Press the lever to open the transformer jaws. When the
pressure on the lever is released, the jaws will close again.
9. Hand Guard
Designed to protect user for safety.
-27-