User Manual
*: Put a low resistor in the input terminal before slide the sliding
function switch to resistor and continuity function may be
cause a buzzer sound
Continuity
Built-in buzzer sound when resistance is less than 50 Ω and sound
off when measured resistance is more than > 300 Ω.
Between 50 Ω to 300 Ω the buzzer maybe sound or off either.
DC A (auto-ranging)
Range
Resolution
Accuracy
0 ~ 40 A 10 mA
±
1,0% rdg. + 2 dgt.
40 ~ 200 A 100 mA
200 ~ 300 A 100 mA
±
2,0% rdg. + 2 dgt.
Overload protection: 400 A
rms
AC A (auto-ranging)
Range Resolution Accuracy Frequency
response
0 ~ 4 A 10 mA
±
1,0 % rdg. +
2dgt.
50 Hz ~ 60 Hz
4 ~ 40 A 10 mA
±
1,0 % rdg. +
3dgt.
40 ~ 200 A 100 mA
200 ~ 300 A 100 mA
±
3,0 % rdg. +
3dgt.
0 ~ 4 A 10 mA
±
2,0 % rdg. +
7dgt.
40 Hz ~ 1 kHz
4 ~ 40 A 10 mA
±
2,0 % rdg.
+5dgt.
40 ~ 200 A 100 mA
200 ~ 300 A 100 mA
±
5,0% rdg.+
5dgt.
Overload protection: 400 A
rms
-24-