User Manual

3.4. AC Current
Range
Resolution
Accuracy
600 µA
0,1 µA
± 1,0% rdg. + 3 dgt.
6000 µA
1 µA
60 mA
100 µA
600 mA
10 mA
± 1,2% rdg. + 3 dgt.
Overload protection:
FF 0,8 A / 1000 V fuse
Frequency - range: 50 ... 400 Hz
All AC current ranges are specified from 5% to 100% of range
3.5. Resistance
Range
Resolution
Accuracy
600
0,1
± 0,5% rdg.+ 4 dgt.
6 k
1
± 0,5% rdg.+ 2 dgt.
60 k
10
600 k
100
6 M
1 k
± 1,5% rdg.+ 8 dgt.
60 M
10 k
Overload protection: 1000 V DC/AC
rms
3.6. Frequency
Range
Resolution
Accuracy
9.999 Hz
0.001 Hz
+1.2 % v.M. + 3 dgt.
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
1 Hz
99.99 kHz
10 Hz
999.9 kHz
100 Hz
9.999 MHz
1 kHz
+1.5 % v.M. + 4 dgt.
Sensitivity: >0.5V RMS while ≤1 MHz;
Sensitivity: >3V RMS while >1MHz;
Input Protection: 1000V DC or 1000V ACrms
-45-