5.1 Description
1. LCD Display
Digital readings are displayed on a 6000 count display with automatic
polarity indication and decimal point placement.
2. Hz/Duty-button
When measuring ac voltage (or ac current), you can press this button
to select frequency, duty cycle or ac voltage (or ac current)
measurement function, and the display will show the relevant symbol.
In frequency or duty cycle measurement mode, you can press this
button to switch between frequency and duty cycle measurements.
3. Max.-MIN – HOLD Function
For measuring the MIN or Max-value make the following steps:
Press the „MIN MAX“ button to display the max. measured value
(MAX-Symbol appears in the LCD)
Press „MAX MIN“ again to display the min. measured value (MIN-
Symbol appears in the LCD)
Press and hold the „MAX MIN“ button for 1 second to leave the
"MIN MAX"-mode.
4. SELECT-button
To select between AC or DC measurements.
5. Function selector
To select the measuring range
6. 10 A - Input Terminal
For current measurements (AC or DC) up to 10 A when the rotary
selector switch is in the 10 A position.
7. mA Input Terminal
For current measurements up to 600 mA DC/AC when the rotary
selector is in the µA or mA position.