7.11. Replacing the fuse
WARNING!
To avoid electric shock, disconnect all the test probes before removing
the fuse. Replace only with the same type of fuse. Not note remove the
top cover. Service should be performed only by qualified personnel.
CAUTION!
For continued protection against fire or other hazard, replace only with
fuse of the specified voltage and current ratings.
Follow these steps to replace the fuse:
1. Turn the meter off and disconnect the test probes.
2. Remove the protection holster.
3. Remove the battery cover by unscrewing the screw and pulling
off the battery cover.
4. Remove the blown fuse.
5. Install the new fuse in the fuse compartment.
F1: 500mA / 600V ; 5x20mm
F2: 10 A / 600V ; 5x20mm
6. Replace the cover and secure it with the screw.
WARNING!
Do not operate your meter until the back cover is in place and fully
closed.