Datasheet
4. Technical data
Display
2-line, 4 4/5-digit LCD-display with max. 50000 counts, function
symbols and backlight
Jaw opening
48 mm (1,9”) max.
Polarity
automatic switchover:
in case of negative readings (-) prior to the measurement display
Over-Range indication
„OL“ is displayed
Low battery indication
is displayed
Measurement rate
2x per second
PEAK detector
>1ms
Input resistance
10M (V DC/AC)
AC-bandwidth
50 to 400Hz (A AC; V AC)
Crest factor
3.0: 50A range
1,4: 1000A range
(at 50/60Hz and 5% to 100% of range)
Thermocouple
Type-K
Fuse
Overload protection for direct current measurement up to
4000µA
500mA/660V; 5x20mm
Auto power off
30 minutes
Operating temperature
5°C ~ 40°C (41°F ~ 104°F) / <80% RH
Operation Altitude
2000m (7000ft.)
Storage temperature
-20°C ~ +60°C (-4°F ~ 140°F) / <80% RH
Battery
9V-battery (NEDA 2604)
Dimensions (WxHxD)
76 x 230 x 40mm
Weight
315g
-32-