Datasheet

5. Measurement functions and ranges
5.1. Specifications
Function
Range
Resolution
Accuracy (% of reading)
DC - Current
60.00 A
10 mA
± (2,5% + 10 digits)
600.0 A
100 mA
± (2,5% + 8 digits)
1000 A
1 A
± (3,0% + 8 digits)
AC - Current
True RMS
(50 Hz to 60 Hz)
60.00 A
10 mA
± (2,5% + 10 digits)
600.0 A
100 mA
± (2,5% + 8 digits)
1000 A
1 A
± (3,0% + 8 digits)
All AC voltage ranges are specified from 5% of range to 100% of range
DC - Voltage
600.0 mV DC
0,1 mV
± (1,0% + 3 digits)
6.000 V DC
1mV
± (1,2% + 3 digits)
60.00 V DC
10 mV
600.0 V DC
100 mV
1000 V DC
1 V
± (1,5% + 3 digits)
AC - Voltage
True RMS
(50 Hz to 1000 Hz)
6.000 V AC
1 mV
± (1,5% + 5 digits)
60.00 V AC
10 mV
600.0 V AC
100 mV
1000 V AC
1 V
± (3,0% + 8 digits)
All AC voltage ranges are specified from 5% of range to 100% of range
Resistance
600.0 Ω
0,1 Ω
± (1,0% + 4 digits)
6.000 kΩ
1 Ω
± (1,5% + 2 digits)
60.00 kΩ
10 Ω
600.0 kΩ
100 Ω
6.000 MΩ
1 kΩ
± (2,0% + 5 digits)
60.00 MΩ
10 kΩ
± (2,5% + 8 digits)
Capacitance
4.000 nF
1 pF
(5,0% + 30 digits)
40.00 nF
10 pF
(5,0% + 20 digits)
400.0 nF
0,1 nF
(3,0% + 5 digits)
4.000 nF
1 nF
40.00 μF
10 nF
400.0 μF
0,1 µF
(4,0% + 10 digits)
4000 µF
10 µF
(4,5% + 10 digits)
-31-