User Manual
4. Technical data
Display 40x45mm Multifunction-LCD-display with max. reading of
40000; function annunciators and bargraph
Jaw opening 52 mm max.
Polarity automatic: switchover in case of negative readings prior to
the measurement display.
Over-Range indication „OL“ is displayed
Low battery indication Battery symbol is displayed
Measurement rate 2x per second
PEAK detector >1ms
Input resistance 10MΩ (V DC/AC)
AC-bandwidth 50 to 400Hz (A AC; V AC) True RMS
Crest factor 3.0: 40/400A ranges
1.4: 1000A range (at 50/60Hz and 5% to 100% of range)
Auto power off 30 minutes
Operating temperature 5°C – 40°C / <80% RH
Operation Altitude 2000m (7000ft.)
Storage temperature -20°C - +60°C / <80% RH
Battery 9V-battery (NEDA 2604)
Dimensions (WxHxD) 105x293x45mm
Weight 536g
-27-