User Manual

3.1. Maximum input values
Function
Max. Input
A AC, D CA 400 A
V DC, V AC 600 V DC/AC
Resistance, diode, continuity test,
frequency, work cycle, capacity
250 V DC/AC
Temperature (°C/°F) 250 V DC/AC
4. Specifications
4.1. DC Volts
Ranges
Resolution
Accuracy
400mV 100 µV
±
0,8% rdg. + 2 dgt.
4 V 1 mV
± 1,5% rdg. + 2 dgt.
40 V 10 mV
400 V 100 mV
600 V 1 V
±
2,0% rdg. + 2 dgt.
Overload protection: 600V AC/DC
Input Impedance: 10 M
4.2. AC Volts
Range
Resolution
Accuracy
400 mV 100 µV
±
1,0% rdg. + 10 dgt.
4 V 1 mV
± 1,5% rdg. + 5 dgt.
40 V 10 mV
400 V 100 mV
600 V 1 V
±
2,0% rdg. + 5 dgt.
Overload protection: 600 V AC/DC
Frequency range: 50/60 Hz
Input Impedance: 10 M
4.3. DC Current
Range
Resolution
Accuracy
40 A 10 mA
±
2,5% rdg. + 5 dgt.
400 A 100 mA
±
2,8% rdg. + 5 dgt.
Overload protection: 400 A
-24-