User Manual

Command code & return
value
Function
Example
Input Command:
GETD[CR]
Return value:
<voltage><current><status>[
CR]
OK[CR]
Get PS Display values of
Voltage, Current and
Status of CC/CV
<voltage>=????
<current>=????
<status>=0/1 (0=CV, 1=CC)
Input command:
GETD[CR]
Return value:
150016001[CR]
OK[CR]
Meaning:
The PS Display value is 15V an
d
16A.
It is in CC mode.
Input Command:
GOVP[CR]
Return value:
<voltage>[CR]
OK[CR]
Get preset upper limit of
output Voltage
<voltage>=???
Input command:
GOVP[CR]
Return value:
111[CR]
OK[CR]
Meaning:
The preset upper limit of output
Vol
tage is 11.1V
Input Command:
SOVP<voltage>[CR]
Return value:
OK[CR]
Preset upper limit of output
Voltage
<voltage>=000<???<Max-
Volt
*Max-Volt value refer to
product specification
Input command:
SOVP151[CR]
Return value:
OK[CR]
Meaning:
Prese
t upper limit of output Voltage
as 15.1V
Input Command:
GOCP[CR]
Return value:
<current>[CR]
OK[CR]
Get preset upper limit of
output Current
<current>=???
Input command:
GOCP[CR]
Return value:
111[CR]
OK[CR]
Meaning:
The preset upper limi
t of output
Current is 11.1A
Input Command:
SOCP<current>[CR]
Return value:
OK[CR]
Preset upper limit of output
Current
<current>=000<???<Max-
Curr
*Max-Curr value refer to
product specification
Input command:
SOCP151[CR]
Return value:
OK[CR]
Meaning:
Preset upper limit of output Current
as 15.1A
-
54
-