User Manual

Vector  : The space between the adjacent sampling points in the display is filled with the vector form. 
Display in the Vector Form 
Dots  : Only the sampling points are displayed. 
Display in the Dots Form 
13.1. XY Mode 
Check "XY Mode", the user interface is switched into Three View mode. Choose the first channel and 
the second channel. In XY mode widow, the first channel is displayed in the horizontal axis and the 
second in the vertical axis. 
Note: XY Mode only support 1K storage memory. The storage memory is set to 1K automatically. 
13.2. Persistence 
When the Persistence function is used, the persistence display effect of the picture tube oscilloscope 
can be simulated. The reserved original data is displayed in fade color and the new data is in bright 
color. 
Different  persistence  time  can  be  chosen:  Off,  0.5  second,  1  second,  2  seconds,  5  seconds  and 
Infinite. When the "Infinite" option is set, the measuring points will be stored till the controlling value is 
changed. Click "Clear" button, the persistence will be cleared. 
Note: 
If  the  time  base,  voltage  division,  deep  memory  is  changed,  or  the  channel  is  turned  off/on,  the 
persistence will be cleared automatically and record the updated waveform. 
13.3. Grid Brightness 
Drag slider to adjust the brightness of grid in the Waveform Display Area. 
-85- 