10.4. The automatic measurement of time parameters 
The  PeakTech
®
  oscilloscopes  provide  time  parameters  auto- measurements  include 
Frequency, Period, Rise Time, Fall Time, +Width, -Width, Delay 1→2   ,  Delay  1→2  , 
+Duty and –Duty. 
Figure shows a pulse with some of the time measurement points. 
Rise Time :  Time that the leading edge of the first pulse in the waveform takes to rise from 10 % to 
    90 % of its amplitude. 
Fall Time  :  Time that the falling edge of the first pulse in the waveform takes to fall from 90 % to 
    10 % of its amplitude. 
+Width  :  The width of the first positive pulse in 50 % amplitude points. 
-Width  :  The width of the first negative pulse in the 50 % amplitude points. 
Delay 1→2:  The delay between the two channels at the rising edge. 
Delay 1→2:  The delay between the two channels at the falling edge. 
+Duty  :  +Duty Cycle, defined as +Width/Period. 
-Duty  :  -Duty Cycle, defined as -Width/Period. 
11. How to Implement Sampling Setup 
Click 
to show Function menu, choose “Sampling” to set sampling mode. 
Samping Mode 
Description 
Sampling 
Normal sampling mode 
Peak Detect 
Use to capture maximal and minimal samples. Finding highest and 
lowest points over adjacent intervals. It is used for the detection of the 
jamming burr and the possibility of reducing the confusion. 
Average 
It is used to reduce the random and don´t-care noises, with the editable 
number (1 ≤ number ≤ 128) of averages. 
-80- 