User Manual
33. How to use Autoscale   
The function is applied to follow-up signals automatically even if the signals change at any time. Autoscale 
enables the instrument to set up trigger mode, voltage division and time scale automatically according to the 
type, amplitude and frequency of the signals. 
Fig. 77 Autoscale menu 
The menu is as follows: 
Function Menu  Setting  Instruction 
Autoscale 
ON 
OFF 
Turn on Autoscale. 
Turn off Autoscale. 
Mode 
Follow-up and adjust the vertical and horizontal settings. 
Follow-up and adjust horizontal scale without changing vertical setting. 
Follow-up and adjust vertical scale without changing horizontal setting. 
Wave 
Show Multi-period waveforms. 
Only show one or two periods. 
If you want to measure the two-channel signal, you can do as the follows: 
1.  Press Autoscale button, the function menu will appear. 
2.  Press H1 to choose ON. 
3.  Press H2 and choose    for Mode item. 
4.  Press H3 and choose    for Wave item. 
-156- 