User Manual
The description of the cursor measurement menu is shown as the following table:   
Function Menu  Setting  Description 
Type 
OFF 
Voltage 
Time 
Switch off the cursor measurement.   
Display the voltage measurement cursor and menu. 
Display the time measurement cursor and menu.   
Source 
CH1 
CH2 
Display  the  channel  generating  the  waveform  to  which  the  cursor 
measurement will be applied.   
When carrying out the cursor measurement, the position of Cursor 1  can be adjusted with the VERTICAL 
POSITION knob of Channel 1, and that of Cursor 2 can be adjusted with the VERTICAL POSITION knob of 
Channel 2. 
Perform the following operation steps for the voltage cursor measurement of the channel CH1: 
1.  Press Cursor and recall the Cursor Measure menu. 
2.  Press the H2 button and choose CH1 for Source. 
3.  Press the H1 button, the Type menu will display at the right of the screen. Then press the F2 button to 
choose  Voltage  for  Type,  with  two  purple  dotted  lines  displayed  along  the  horizontal  direction  of  the 
screen, which indicating Cursor1 and Cursor2. 
4.  According  to  the  measured  waveform,  adjust  the  positions  of  Cursor1  and  Cursor2  by  turning  the 
VERTICAL POSITION knob of CH1 and CH2. Cursor increment window at the left bottom of waveform 
shows absolute value of D-value of cursor 1 and cursor 2 and the present position of the two cursors. (see 
Fig. 72). 
Fig. 72 Waveform of Voltage Cursor Measurement 
-152- 