User Manual
6. Data width queue trigger:
Fig. 87 Duration trigger menu
Make BUS as trigger source and continuous duration in BUS as trigger condition to generate trigger. Duration
trigger menu refer to Fig. 87.
Duration trigger function as below:
Function
Setting
Instruction
Source
BUS0~BUS3
Select the trigger source from BUS0~BUS3
Code
0x0000~0xffff
(HEX)
0~65535
(DEC)
Can be set discretionarily between 0x0000 and 0xffff (HEX) or between
0 and 65535 (DEC) according to the bus and code setting.
Duration
10 ns ~ 50 s
The duration width can be set from 10ns (1-2-5) to 10.00us (1-2-5)
according to the sampling rate from high to low.
Qualifier
>=
<=
Trigger occur on condition that the bus value is equal to the code type
and the duration is more than or equal to the duration width.
Trigger occur on condition that the bus value is equal to the code type
and the duration is less than or equal to the duration width.
-199-