1. Safety Precautions
This product complies with the requirements of the following European Community Directives: 2004/108/EC
(Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) as amended by 2004/22/EC (CE-Marking).
Overvoltage category II 1000V; pollution degree 2.
CAT I: For signal level, telecommunication, electronic with small transient over voltage
CAT II: For local level, appliances, main wall outlets, portable equipment
CAT III: Distribution level, fixed installation, with smaller transient overvoltages than CAT IV.
CAT IV: Units and installations, which are supplied overhead lines, which are stand in a risk of persuade of a
lightning, i.e. main-switches on current input, overvoltage-diverter, current use counter.
To ensure safe operation of the equipment and eliminate the danger of serious injury due to short-circuits
(arcing), the following safety precautions must be observed.
Damages resulting from failure to observe these safety precautions are exempt from any legal claims
whatever.
* Do not use this instrument for high-energy industrial installation measurement. This instrument is intended
for use in installation over voltage category II.
* The instrument must be set up so that the power plug can be removed from the socket easily.
* Prior to connection of the equipment to the mains outlet, check that the available mains voltage
corresponds to the voltage setting of the equipment.
* Connect the mains plug of the equipment only to a mains outlet with earth connection.
* Do not place the equipment on damp or wet surfaces.
* Do not place water filled containers on the equipment (danger of short-circuit in case of knock over of the
container).
* Do not exceed the maximum permissible input ratings (danger of serious injury and/or destruction of the
equipment).
* The meter is designed to withstand the stated max voltages. If it is not possible to exclude without that
impulses, transients, disturbance or for other reasons, these voltages are exceeded a suitable presale (10:1)
must be used.
* Disconnect test leads or probe from the measuring circuit before switching modes or functions.
* Do not conduct voltage measurements with the test leads connected to the mA/A- and COM-terminal of the
equipment.
* The 10A-range is protected. To avoid damage or injury, use the meter only in circuits limited by fuse or
circuit breaker to 10A or 2000VA.
* To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking
any resistance measurements.
* Do not conduct current measurements with the leads connected to the V/-terminals of the equipment.
* Check test leads and probes for faulty insulation or bare wires before connection to the equipment.