Datasheet
5.2. Resetable fuse 
The  PeakTech
®
  1020 is  supplied  with  an automatic  circuit  breaker,  by  this 
means any changing of fuses is not needed. If the current is higher than the 
measuring range of the unit, the inputs will be cut off. When the current falls 
down in the 200mA-range, so the value will be shown in the LCD. 
5.3. Preliminary Note 
1.  To  check  the  batteries  please  switch  on  the  DMM.  If  the    battery  is 
weak, a "BAT" sign will appear on the  right of Display. If this does not 
appear  on  the  display  proceed  as  below.  See  "Maintenance"  if  the 
battery has to be replaced. 
2.  The warning sign next to the test leads jack is for warning that the input 
voltage  or  current  should  not  exceed  the  indicated  values.  This  is  to 
prevent damage to the internal circuitry. 
3.  The function switch should be set to the range which you want to test 
before operation. 
5.4. DC Voltage Measurement 
1.  Set the function switch to the V position. 
2.  Press the MODE-button to indicate “DC” on the display. 
3.  Touch the black test probe tip to the negative side of the circuit. Touch 
the red test probe tip to the positive side of the circuit. 
4.  Read the voltage in the display. 
Note: 
1.  When  only  the  figure  "OL" is  displayed, overrange is being  indicated 
and the Function switch must be set to a higher range. 
2.  CAUTION:  Do  not  apply  more  than  600  V  to  the  input.  Indication  is 
possible at higher voltages but there is danger of damaging the internal 
circuitry. 
3.  Use  extreme  caution  to  avoid  contact  with high  tension  circuits  when 
measuring high voltage. 
-24- 