User Manual

- 83 -
LAN interface
Direct connection to the LAN input of the PC:
1. Connection: Plug the LAN cable into the LAN port on the back of the oscilloscope. Plug the other end
into the LAN port of the PC.
2. Setting the computer's network parameters: Since the oscilloscope does not support automatic IP
address retrieval, you must assign a static IP address. In the following example, we set the IP address
to 192.168.1.71 and the subnet mask is 255.255.255.0.
3. Setting the network parameters of the PeakTech
®
oscilloscope software:
Run the software on the computer. From the Communications menu, select Ports-settings. Set the
Connect using option to LAN. The first three bytes of the IP address are the same as the IP address in
step (2). The last byte should be different. In this example, we set the address to 192.168.1.72. The setting
range of the port number is 0 ~ 4000, but since a port lower than 2000 is always used, it is recommended
to set a value higher than 2000. In this example, we use 3000.
-