User Manual

- 78 -
6. multimeter
Input sockets
The input sockets of the digital multimeter are located on the back of the unit and are marked accordingly
with 10A, mA, COM and V/Ω/C.
DMM menu
Press the DMM button on the front of the unit to switch the multimeter function on and off. When the
multimeter function is on, this button is illuminated.
The multimeter menu is described below:
Menu
Setting
Description
Current
ACA
DCA
AC current measurement
DC current measurement
Voltage
ACV
DCV
AC voltage measurement
DC voltage measurement
R
R
C
Resistance measurement
Diode measurement
Capacity measurement
On-Off
Switches to continuity test (On-Off measurement)
Configure
Hold
ON OFF
Freezes the measured value acquisition
Show Info
ON OFF
Shows/hides the multimeter window
Fashion
Car Manu
Selects automatic or manual mode
Relative
Sets the current measurement value to zero. The measurement
is the difference value of the reference value to the current
measurement display.
Current
mA 10A
Selects the current measuring range