User Manual

- 38 -
4. pulse width trigger
The pulse trigger lets the oscilloscope trigger according to the pulse width of the signal. Unusual signals
can be detected by adjusting the pulse width conditions.
In pulse trigger mode, the setting information is displayed at the bottom right of the screen, e.g.:
indicates that pulse trigger on CH1 with DC coupling has been selected and the polarity
is positive and the trigger level is 0.00mV.
Pulse Trigger menu:
Menu
Setting
Description
Trigger mode
Pulse
Set vertical trigger type as pulse triggering
Source
CH1
CH2
Channel 1 as trigger signal.
Channel 2 as trigger signal.
Coupling
AC
DC
Blocks the DC component.
Allows all components to pass through.
When
Select polarity
Select the pulse width conditions with the Multi ( ) knob
or touch +/- for the time setting and to move the
cursor.
Fashion
Holdoff
Car
Normal
Single
Holdoff
Reset
Capture waveform even if no trigger occurs
Capture waveform when a trigger occurs.
When trigger occurs capture a wave and then stop it
100ns~10s, use the Multi ( ) knob to set the time interval
before another trigger occurs.
Set the holdoff time as 100ns.
5. runt trigger
With the runt trigger, pulses are detected that run through one trigger level but not through another, as
shown in the graphic.
In run-trigger mode, the setting information is displayed at the bottom right of the screen, e.g.:
indicates that the run-trigger on CH1 has been selected with positive polarity and the
difference between the up-level and low-level threshold is 0.00mV.