Z method
The Z method is recommended for pipe diameters of 300 to 500 mm.
Top view of pipe
1 Upstream transducer
2 Spacing
3 Flow direction
4 Downstream transducer
W method
The W method is suitable for measurements of plastic pipes with diameters of 20 to 100 mm.
Top view of pipe
1 Upstream transducer
2 Spacing
3 Downstream transducer