Installation guide
1 2
Y
Z
©
X
!
3
C00070
PYIP PY2P
CORNER # 018 024 030 036 042 048 060 024 030 036 042 048 060
1 47.3 53.2 53.2 59.7 67.5 78.9 85.5 55.1 59.5 61.0 72.6 80.0 88.9
2 44.8 50.4 50.4 56.5 63.9 74.7 81.0 52.2 56.3 57.8 68.8 75.8 84.2
3 77.2 86.8 86.8 97.3 110.1 128.7 139.5 89.9 97.0 99.5 118.4 130.5 145.1
4 79.7 89.6 89.6 106.5 113.6 132.8 144.0 92.8 100.2 102.7 122.2 134.7 149.8
TOTAL WEIGHT 249 280 280 320 355 415 450 290 313 321 382 421 468
Fig. 5--PYIP and PY2P Unit Corner Weights
I
EVAP. COND.
COIL COIL
Fig. 6--Slab Mounting Details
C99014
HOOK
FEED
Fig. 7A--Threading Bolt for Rigging
C99067
The condenser fan pulls air through the condenser coil and discharges it through the top cover. Be sure that the fan discharge does not recirculate
to the condenser coil. Do not locate the unit in either a corner or under an overhead obstruction. The minimum clearance under a partial overhang
(such as a normal house overhang) is 48-in. above the unit top. The maximum horizontal extension of a partial overhang must not exceed 48-in..
Do not place the unit where water, ice, or snow from an overhang or roof will damage or flood the unit. Do not install the unit on carpeting, tile,
or other combustible materials. The unit may be installed on wood flooring or on Class A, B, or C roof covering materials.