User guide

Software conguration
• Run the Net2 software.
• Check that the ACU has been detected by looking in the Doors screen. The rmware in the ACU's will be
automatically updated to the same revision as the PC. Do not make any changes to the software during this phase.
• Once this has nished, each ACU must be congured (as below)
Reader 1: Settings for Reader 1 and Keypad 1 on the ACU.
Reader 2: Settings for Reader 2 and Keypad 2 on the ACU.
Alarm: Contains settings for the different types of alarm.
Codes: Valid codes can be viewed, added and removed.
(Can only be viewed when a keypad is active).
Events: Shows the events for the control unit selected.
Door name: Name the ACU.
Door open time: Set the door open time.
Unlock the Door during: Permanently unlocks the door while
this timezone is active. - Should be set to 'At No Time' for
normal user operation.
Name: Each reader can be named individually if required.
Reader type: Set the reader type, if applicable.
Keypad type: Set the keypad type, if applicable.
Token data format: Select the data type being used on the
system. (New formats can be created).
Reader operating mode: Set the operating mode.
Timed operating modes: A different operating mode can be
congured within a time window.
Reader action: Set the action required when access is granted.