Standard Syntax Guidelines
When creating MPCLII packets:
N
Begin each packet with a start of header ({).
N
End each packet with an end of header (}).
N
Define no more than 200 fields in a format. Each p indicates
one field. However, options are not counted as fields.
N
The field number (0 - 999) must be unique. Monarch
recommends starting at 1, instead of 0.
N
Do not use a field number more than once per format.
N
Define all fields in the order you want to image/print them.
N
Separate all parameters with a Parameter Separator (,).
N
End each field with a Field Separator ( p ).
N
Enter all information in CAPITAL letters, except words or
phrases within quotation marks.
N
Include all parameters for a field unless documented as
optional.
N
Define non-printable text fields before the field to which they
apply.
N
Define options immediately after the field to which they apply.
N
Multiple options can be used with most fields. Options can be
used in any combination except as noted with each definition.
N
Keep in mind that proportionally spaced fonts need wider
fields than monospaced fonts. For variable field data, use a
letter "W" to determine the maximum field size.
N
Do not place a new line (return) or any other non-printing
character within a field definition. However, a carriage return
or line break after each p makes your formats easier to read.
T,1,20,V,30,30,1,1,1,1,B,C,0,0,0 p
T,2,10,V,50,30,1,1,1,1,B,C,0,0,0 p
N
Spaces are ignored, except within character strings.
2-4