USER MANUAL MODEL 1075 KiloModem II AC Powered, High-Speed X.21 Short-Range Modem Part #07M1075-B Doc: 054081UB Revised 6/16/97 CERTIFIED An ISO-9001 Certified Company SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.
1.0 WARRANTY INFORMATION 1.3 SERVICE Patton Electronics warrants all Model 1075 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above.
2.0 GENERAL INFORMATION 3.0 CONFIGURATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Customer Service at (301) 975-1007. The Model 1075 is easy to install and is ruggedly designed for excellent reliability.
Switches S2-1 and S2-2: Data Rate 3.1.1 Configuration Switch Set “S1” The switches on Switch S1 set V.54 Test Functions. Default settings and detailed descriptions for each switch are shown below. Position S1 SUMMARY TABLE Function S1-1 thru S1-7 Not Assigned Off S1-8 V.54 Test Functions Off Factory Default Enabled Switches S2-1 and S2-2 are set in combination to determine the synchronous data rate for the Model 1075.
3.2 CONFIGURATION STRAPS 3.2.2 Location of the Internal Straps In addition to the configuration switches described above, the Model 1075 is also equipped with two internal straps that set the DTE/DCE Configuration and the DB-15 Shield. In order to configure these straps, you must open the Model 1075 case. Figure 5 (below) shows the location of the DCE/DTE switch and the JP1 strap on top side of the the PC board.
4.0 INSTALLATION 3.2.4 Setting the JP1 Shield Strap The setting of JP1 determines whether the shield (pin 1) of the X.21 interface is connected signal ground. In the default setting, DB-15 shield is connected to signal ground. The X.21 shield is not connected to signal ground when the jumper is placed on pins 1 and 2 . See Figure 7, below. 4.1 CONNECTION TO THE TWISTED PAIR INTERFACE The Model 1075 supports full or half duplex communication between two X.21 devices at distances to 6 miles (9.
When connecting two Model 1075s, it is necessary to use a "crossover" cable. The diagram below shows how a cross-over cable should be constructed for an environment where both Model 1075s use a 8wire RJ-45 connector. Similar logic should be followed when using RJ11 connectors or a combination of the two. 4.3 AC POWER CONNECTIONS Power is supplied to the Model 1075 by a 9 VDC, 1 A wall mount transformer. This transformer connects to the Model 1075 by means of a cannon jack on the rear panel.
5.0 OPERATION 5.2 TEST MODES Once the Model 1075 is properly configured and installed, it should operate transparently—as if it were a standard cable connection. Section 5.0 describes the LED status monitors and the built-in V.52 and V.54 test modes. The Model 1075 is powered by a 9V DC external wall mount transformer. To power up the unit, connect the power supply cord to the power jack on the rear of the Model 1075 and plug the power adapter into the wall. There is no ON/OFF switch. 5.
APPENDIX A C. If the BER test equipment indicates a fault, and the Local Analog Loopback test was successful for both Model 1075s, you may have a problem with the twisted pair line between the modems. You should then check the twisted pair line for proper connections and continuity. 5.2.3 How to Use the V.52 BER Test Independently The V.52 BER test can be used independently of the V.54 loopback tests.
APPENDIX B APPENDIX C MODEL 1075 FACTORY REPLACEMENT PARTS AND ACCESSORIES MODEL 1075 X.21 Interface DB15 Female Description Patton Model # 1075 ................................KiloModem II X.21 Short Range Modem 0805B ..............................120V Wall Mount AC Adapter 08059DCI ........................230V AC Adapter (No Power Cord) 0805US ...........................American Power Cord 0805EUR.........................European Power Cord CEE 7 0805UK ...........................
APPENDIX D Dear Valued Customer, MODEL 1075 PIN CONFIGURATIONS BLOCK DIAGRAM Thank you for purchasing Patton Electronics products! We do appreciate your business. I trust that you find this user manual helpful.