USER MANUAL MODEL 1092A High Speed, 2-Wire/4-Wire, Sync & Async Short Range Modem Part# 07M1092A-E Doc# 033031UD Revised 03/29/00 An ISO-9001 Certified Company SALES OFFICE (301)975-1000 TECHNICAL SUPPORT (301)975-1007 http://www.patton.
TABLE OF CONTENTS Section 1.0 WARRANTY INFORMATION Page 1.0 Warranty Information .............................................................2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service 2.0 General Information ...............................................................4 2.1 Features 2.2 Description 2.3 SNMP 3.0 Configuration..........................................................................6 3.1 Configuring the Hardware DIP Switches 3.1.1 Configuration DIP Switch Set “S1” 3.1.
2.0 GENERAL INFORMATION 1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at: tel: (301)975-1007; email: support@patton.com; or, www: http://www.patton.com. NOTE: Packages received without an RMA number will not be accepted.
3.0 CONFIGURATION 2.3 1092A SNMP MANAGEMENT SOLUTIONS Model 1092A is SNMP manageable when it is connected to a rack-mounted Model 1092ARC . SNMP management is enabled through a 1001MC rack management card located in the Patton Electronics Rack System. 2.3.1 HTTP/HTML Management The 1001MC maintains HTML pages that can be viewed through a web browser.
3.1.1 Configuration DIP Switch Set “S1” Switch S1-3: Data Set Ready During Line Loopback Test Use the eight switches in DIP Switch Set “S1” to configure the data rate, asynchronous or synchronous data format, transmit clock source and response to RDL request. The following table summarizes default positions of DIP Switch S1. Detailed descriptions of each switch follow the table. Use Switch S1-3 to control the behavior of the DSR signal at the EIA interface during the line loopback test.
Switch S1-8: Response to RDL Request Use Switch S1-8 to allow Model 1092A to enter the Remote Digital Loopback diagnostic test when requested to do so by the far end Model 1092A For example, when Switch S1-8 is set to “ON”, it will enter RDL mode (See Section 5.3.2) when requested to do so by the remote Model 1092A. S1-8 On Off 3.1.
3.2 CONFIGURING THE SOFTWARE SWITCHES The Model 1092A features a menu-driven command system that allows you to configure the local 1092A. Follow the instructions below to configure the Model 1092A using the software switches: 1) Connect the serial RS-232 port of a V100 or similar DTE with terminal emulation to the EIA/TIA-561l port of the Model 1092A. To construct an RS-232 to EIA-561 patch cable, refer to the control port pinout diagram in Appendix D.
MAIN MENU Option 2: Display Hardware Configuration MAIN MENU Option 4: Setup Software Configuration Select Option 2 to display the configuration of the hardware DIPswitches. To use the Hardware Configuration for the Active Configuration, select MAIN MENU Option 5. Then select “Use Hardware DIP-Switches”. Finally, select MAIN MENU Option 8 to save the changes. Select Option 4 to edit the software configuration of the Model 1092A.
2. Data Format 4. DSR During Local Line Loop Select Option 2 in the SOFTWARE CONFIGURATION Menu to select the async or sync data format (See below). Select Option 4 in the SOFTWARE CONFIGURATION to configure the behavior of the local Data Set Ready (DSR) signal during the Local Line Loop test mode (below). 3. Clock Mode 5. Response to Remote Digital Loop Select Option 3 in the SOFTWARE CONFIGURATION Menu to select the sync clock mode (See below).
7. DTE Controlled Remote Digital Loop MAIN MENU Option 6: Display Modem Status Select Option 7 in the Menu to enable DTE control of the Remote Digital Loop Menu (See below). The Select Option 6 from MAIN MENU to display the Modem Status (below). Press the space bar on the keyboard to update and redisplay the screen. interface by selecting Enable (Option 1). To instruct the 1092A to ignore this request from the DTE interface, select Disable (Option 2).
4.0 INSTALLATION The Model 1092A Test Modes are described on the following page. To run or terminate a particular test, key in the option to get to that screen menu. Once the Model 1092A is properly configured, it is ready to connect to the twisted pair interface, to the serial port, and to the power source. This section tells you how to make these connections. 4.1 CONNECTING THE TWISTED PAIR INTERFACE OFF Terminates all tests 511 Initiates the built-in test pattern generator and detector.
3. Proper 2-Wire Pairing between the two modems is as follows: SIGNAL PIN# PIN# TIP RING 4 ----------------------------------------4 5 ----------------------------------------5 SIGNAL TIP RING 4.2 CONNECTING THE SERIAL PORT The serial port interface on the Model 1092A uses interchangeable QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other.
4.2.4 Configuring the X.21 QuikConnect™ Module 2) Hold the module with the faceplate toward you and align the module with the guide slots in the rear panel of the Model 1092A. 3) While keeping the module’s faceplate parallel with the Model 1092A rear panel, slide the module straight in – so that the card edge contacts line up with the socket inside the chassis. NOTE: The card edge connector should meet the socket when it is almost all the way into the chassis.
5.0 OPERATION 4.3.2 Connecting to a DC Power Source The 48 VDC power supply option uses a 3-pin terminal block with spring-type connectors. Please refer to the Model 1090 Series Service Manual. WARNING! There are no user-serviceable parts in the power supply section of the Model 1092A. Voltage setting changes and fuse replacement should only be performed by qualified service personnel. Contact Patton Electronics Technical support at (301)975-1007, via our web site at http://www.patton.
been placed in Test Mode. The unit can be placed in test mode by the local or remote user. NS Glow red to indicate that the local Model 1092A has not yet connected with the remote 5.3 TEST MODES The Model 1092A offers two proprietary loopback test modes, plus a built-in V.52 BER test pattern generator, to evaluate the condition of the modems and the communication link. These tests can be activated physically from the front panel, or via the interface. 5.3.
APPENDIX A 5.3.3 Using the V.52 (BER) Test Pattern Generator To use the V.52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions: 1. 2. Locate the “511/511E” toggle switch on the front panel of the 1092A and move it UP. This activates the V.52 BER test mode and transmits a “511” test pattern into the loop. If any errors are present, the local modem’s red “ER” LED will blink sporadically.
APPENDIX B APPENDIX C PATTON ELECTRONICS MODEL 1092A FACTORY REPLACEMENT PARTS AND ACCESSORIES PATTON ELECTRONICS MODEL 1092A INTERFACE PIN ASSIGNMENT Description Patton Electronics Model # IM1/A...............................V.24 with DB25F IM1/B ...............................RS422/RS530 with DB25F IM1/C...............................V.35 with M34F IM1/D...............................X.21 with DB15F IM1/E ...............................V.35 with DB25F IM1/F ...............................64KG.
APPENDIX C APPENDIX C PATTON ELECTRONICS MODEL 1092A INTERFACE PIN ASSIGNMENT (Continued) PATTON ELECTRONICS MODEL 1092A INTERFACE PIN ASSIGNMENT (Continued) V.35 Interface (M/34F Female Connector) (DCE Configuration) Signal Pin # B ...........................SGND (Signal Ground) C ...........................RTS (Request to Send) D ...........................CTS (Clear to Send) E ...........................DSR (Data Set Ready) F............................CD (Carrier Detect) H .........................
APPENDIX E APPENDIX D PATTON ELECTRONICS MODEL 1092A CONTROL PORT PIN ASSIGNMENT The 1092A control port is an 8 position connector, compliant with EIA/TIA-561. Pin Function RJ45 Pin No. Ground 4 Receive data (to DTE) 5 Transmit data (from DTE) 6 PATTON ELECTRONICS MODEL 1092A QUICK START GUIDE 1) To perform a hardware reset, turn the power off and set configuration switch (S1-6 and 7 “OFF"). 2) Turn on the power for 5 or 10 seconds.