Assembly Instructions

Patterson Fan Company, Inc
Blythewood, SC 29016
www.pattersonfan.com
800.768.3985
Note: The 6ALG2 fan head is equipped with OSHA
compliant nger guards. Mount the fan at desired
height making sure the fan is not in the headway of
personnel preferably out of reach. These fans are pow-
erful and should not be mounted too close to person-
nel at work stations.
1. See yoke mount instruction for yoke to fan
assembly.
2. Assemble the column wall bracket as follows.
Secure Part A (horizontal bottom strut) to the
solid surface from which you will hang the fan
either a wall or column using appropriate wall
anchor (not included). This Part A has a wall
mount bracket with a 4 hole pattern for mounting
to surface.
3. Secure Part B to the wall allowing the bolt hole
to lineup where the fan yoke will be bolted to the
column wall bracket. The fan head and yoke are
suspended below the column wall bracket
allowing full 360° rotation left and right.
4. Secure the “U” shaped yoke to the end of the
column wall bracket where Part A and Part B
converge using the bolt supplied. The yoke
allows a 30+- degree tilt toward the oor for
directing air throw as desired.
5. Safety cable is mandatory. Use a length of
chain of cable to secure the fan to a solid
surface and attach the fan. Make sure cable
or chain is rated for the weight and purpose.
CW Column Wall Mount Assembly Instructions 34” Only