Installation Instructions
Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
● Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or
switching off circuit breaker).
● Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to contact
any surface having a sharp edge. To do so may damage or cut the wire insulation, which could cause serious injury
or death from electric shock.
CAUTION
● All electrical connections must be in agreement with local codes, ordinances or the national electric code (NEC).
Contact your municipal building department to learn about your local codes, permits and/or inspections.
● Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC. Consult a qualified electrician
before installation.
● Do not connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use
a fixture in a two-wire system that is not grounded. If you are not sure your lighting system has a grounding means,
do not attempt to install this fixture. Contact a qualified, licensed electrician for information with regards to proper
grounding methods as required by the local electrical code in your area.
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble,
install or operate the product. Contact customer service for replacement parts.
Tools Required for Assembly (not included): Screwdriver, Phillips Screwdriver, Pliers, Electrical Tape, Wire Cutters,
Safety Glasses, Ladder, Wire Stripper.
Page 2 of 3
SAFETY INFORMATION
ASSEMBLY INSTRUCTIONS
PREPARATION
Turn off the power at fuse or circuit box.
Turn on the power at fuse or circuit box.
A
DD
AA
3
3. Attach the fixture(A) to the
mounting unit(AA) by
inserting two fixture mounting
screws, and then secure
it with two ball nuts(DD).
4. Attach the glass shades(B) to
the glass holders, and then
secure them with socket rings.
Install 2X60W Max medium
base bulbs (not included).
1. Attach mounting unit (AA) to the
outlet box using two mounting
screws(BB). Adjust the length of
the fixture mounting screws if
necessary.
Note: Make sure that the
headless screws are lined up
horizontally to make the fixture
level.
AA
BB
1
1
Fixture
Mounting
Screw
2. Connect the fixture black wire to
the house black wire and the
fixture white wire to the house
white wire using wire connectors
(CC) provided. Connect the copper
wire on the light fixture to the
mounting unit(AA) by securing it
with the preinstalled grounding
screw, and then connect it to the
house grounding wire with the wire
connector(CC).
Tuck all the wires into outlet box.
CC
AA
2
1
4
B
Bulb Type A Max.60W
(not included)
Socket Ring
Glass Holder