Installation Instructions

Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
● Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or
switching off circuit breaker).
● Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to contact
any surface having a sharp edge. To do so may damage or cut the wire insulation, which could cause serious injury
or death from electric shock.
CAUTION
● All electrical connections must be in agreement with local codes, ordinances or the national electric code (NEC).
Contact your municipal building department to learn about your local codes, permits and/or inspections.
● Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC. Consult a qualified electrician
before installation.
● Do not connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use
a fixture in a two-wire system that is not grounded. If you are not sure your lighting system has a grounding means,
do not attempt to install this fixture. Contact a qualified, licensed electrician for information with regards to proper
grounding methods as required by the local electrical code in your area.
PREPARATION
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble,
install or operate the product. Contact customer service for replacement parts.
Tools Required for Assembly (not included): Slotted Screwdriver, Phillips Screwdriver, Pliers, Electrical Tape, Wire
Cutters, Safety Glasses, Ladder, Wire Stripper.
This LED bulb is dimmable with a forward phase electronic dimmer. Dimmers tested to be compatible with this
fixture are the Lutron: TGCL-153PH, MACL-153MH, SCL-153P, DVWCL-153PH.
If you are unfamiliar with electrical installation, it is recommended to use a qualified electrician for your installation(s).
210826
Page 2 of 3
ASSEMBLY INSTRUCTIONS
Turn off the power at fuse or circuit box.
SAFETY INFORMATION
2. Attach mounting plate unit
(AA) to the outlet box using
two mounting screws (BB).
Adjust the length of the
preinstalled fixture mounting
screws if necessary.
1. Unscrew the two bolt nuts (DD).
Remove the mounting plate
unit (AA) from the canopy (A).
3. Pull out the source wires from
the outlet box. Make wire
connections using wire
connectors (CC) as follows:
• Connect the hot wire (black
insulation) from the fixture to
the black wire from the power
source.
• Connect the neutral wire
(white insulation) from the fixture
to the white wire from the power source.
• Attach the fixture ground wire (bare wire)
to the mounting plate unit (AA) with the green ground
screw. Then, depending on local code, connect it to
the house ground wire with the wire connector (CC).
Carefully put all of the wires back into the outlet box.
4. Secure the canopy (A) to the
mounting plate unit (AA) by
inserting the fixture mounting
screws, then secure it with
two bolt nuts (DD).
1
AA
A
DD
4
AA
A
Fixture
Mounting
Screw
DD
2
AA
Outlet Box
Fixture
Mounting
Screw
BB
Green
Ground
Screw
AA
CC
3