Installation Instructions
PREPARATION
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble,
install or operate the product.
Tools Required for Assembly (not included): Slotted Screwdriver, Phillips Screwdriver, Pliers, Electrical Tape, Wire
Cutters, Safety Glasses, Ladder, Wire Stripper.
Page 2 of 3
201119
ASSEMBLY INSTRUCTIONS
Turn off the power at fuse or circuit box.
3. Insert the housing into ceiling
through the mounting hole.
1
4. Hold housing flush against
the ceiling and push out clips,
to fasten the fixture to the
ceiling. Make sure to fully
push clips until they lock into
place.
1. Locate a suitable position to
place the fixture and open in
accordance to the cut-hole
dimensions. A template is
provided to assist in properly
locating and cutting the hole.
2
Hardwire Box
Black To
Black
White To White
Ground To
Ground
Electrical Connection
Knock-out
2. Connect electrical wires.
● Remove the appropriate
knock-out (s) to
accommodate the type of
electrical service to be used.
● Insert electrical supply cables
through knock-out into the
hardwire box.
● Use quick connects push-in terminals to connect
ground wire of supply cable to ground wire (bare copper)
on fixture.
Connect black wire of supply cable to black wire of fixture.
Connect white wire of supply cable to white wire of fixture.
● Place all wires and connections back into the hardwire
box and replace cover.
Note: Supply wire insulation must be rated for at least
90˚C.
Clip
3
Housing(can)
Remodel Clip
4
CEILINGS: Under UL 1598 the following applications exist for fixtures.
SUSPENDED CEILING
Fixture can be installed in suspended
ceilings that are not permanent or
insulated.
S-TYPE
IC-TYPE
INSULATED CEILING
The insulated ceiling or I.C. approved
recessed fixture is one that can be
installed in direct contact with
insulation.
T-TYPE (NON-IC TYPE)
THERMAL PROTECTED
Thermal protected fixture is designed for installation where
will not come in direct contact with insulation. Thermal
insulation must be kept 3” away from housing includes a
thermal protector that deactivates the unit if an incorrect
lamp is used or if insulation is too close to the fixture.