Installation Instructions

Page 3 of 3
200325
DISCLAIMER
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor
to provide directions for meeting every possible contingency during installation, operation or maintenance. When
additional information is desired to satisfy a problem not covered sufficiently for use’s purpose, please contact a
qualified electrician.
FIVE-YEAR LIMITED WARRANTY: If, during normal use, this PATRIOT LIGHTING lighting fixture breaks or fails
due to a defect in material workmanship within five (5) years from the date of original purchase, simply bring this
lighting fixture with the original sales receipt back to your nearest MENARDS retail store. At its discretion, PATRIOT
LIGHTING agrees to have the product or any defective part(s) repaired or replaced with the same or similar PATRIOT
LIGHTING product or part free of charge, within the stated warranty period, when returned by the original purchaser
with original sales receipt. This warranty; (1) excludes expendable parts including but not limited to light bulbs; (2) does
not cover damage that has resulted from abuse or misuse; and (3) does not cover any losses, labor, injuries to
persons/property or costs. This warranty does give you specific legal rights and you may have other rights, which vary
from state to state.
R
R
R
R
Questions, problems, missing parts?
Before returning to your retailer, call our customer service at 1-800-887-6326
Monday – Friday 9:00 a.m. – 5:00 p.m. CST
2
Rectangular knock-outs for
non-metallic cable
Round knock-outs
for metal conduit
3. ELECTRICAL CONNECTION:
Remove junction box cover and appropriate knockout(s) to accommodate respective
electrical service. Luminaire has been designed to accommodate metallic conduit and
non-metallic cable, metallic conduit must be used if local code requires it. Round
knockouts are dedicated for metallic cables and rectangular knockouts are to be utilized
for non-metallic cables. Connect supply leads to wires in fixture junction box. Connect
white to white, black to black and green supply wire to bare copper wire. Provide electrical
service to fixture per NEC and local electrical code from a suitable junction box to junction
box located on fixture. Fixture must be supplied with wire rated for at least 90°C.
(See Fig 2)
Note: This housing can match with an incandescent bulb or LED bulb.