Installation Instructions
Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
● Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or
switching off circuit breaker).
● Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to contact
any surface having a sharp edge. To do so may damage or cut the wire insulation, which could cause serious injury
or death from electric shock.
CAUTION
● All electrical connections must be in agreement with local codes, ordinances or the national electric code (NEC).
Contact your municipal building department to learn about your local codes, permits and/or inspections.
● Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC. Consult a qualified electrician
before installation.
● Do not connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use
a fixture in a two-wire system that is not grounded. If you are not sure your lighting system has a grounding means,
do not attempt to install this fixture. Contact a qualified, licensed electrician for information with regards to proper
grounding methods as required by the local electrical code in your area.
● This fixture is dimmable with a forward phase electronic dimmer. Dimmers tested to be compatible with this fixture are
the Lutron: DVWCL-153PH, MACL-153MH, SCL-153P, TGCL-153PH.
If you are unfamiliar with electrical installation, it is recommended to use a qualified electrician for your installation(s).
PREPARATION
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble,
install or operate the product.
Tools Required for Assembly (not included): Screwdriver, Phillips Screwdriver, Pliers, Electrical Tape, Wire Cutters,
Safety Glasses, Ladder, Wire Stripper.
Page 2 of 4
SAFETY INFORMATION
191031
ASSEMBLY INSTRUCTIONS
2. Pull out the source wires from
the outlet box. Make wire
connections using wire
connectors (CC) as follows:
● Connect the black wire from
the fixture to the black wire
from the power source.
● Connect the white wire from
the fixture to the white wire
from the power source.
● Connect the fixture ground wire to the house
ground wire.
Carefully put the wires back into the outlet box.
Turn off the power at fuse or circuit box.
A. For Ceiling Mounting
1. Attach mounting plate (AA) to
the outlet box using two
mounting screws (BB).
Turn off the power at fuse or circuit box.
BB
AA
Outlet Box
1
AA
CC
Outlet Box
2
Notice: Please toggle the dip switch to
select the CCT before installation.
CCT selectable
by dip switch
2700K 3000K 3500K 4000K 5000K
5 CCT selectable
Fig.A