Installation Instructions
Using template, scribe circle on ceiling in desired loca-
tion.
Accurately cut hole in ceiling
Provide electrical service with exible cable only. Pass
cable through opening and wire xture in accordance
with NEC or your local electrical code. Fixture must be
supplied with wire rated for at least 90°C. (See drawing
for wiring diagram)
Connect supply leads to wires in xture junction box.
Connect white to white, black to black and green supply
wire to bare copper wire.
With clips seated properly inside can (Figure 1) insert
remodel housing into ceiling junction box rst.
Hold xture up against ceiling and push clip through
housing slot.
To lock clips, insert a at-tip screwdriver into notch of
clip and push upward (Figure 2).
To release, pull down on clip (Figure 3).
Install trim. Use only trims specied on product label.
(sold separately)
STEP 1
STEP 2
STEP 3
STEP 4
STEP 6
STEP 7
STEP 8
STEP 9
STEP 10
MH- INSTALLATION INSTRUCTIONS
12.21.12
4, 5 & 6” REMODEL HOUSING
(Figure 1)
To Install
(Figure 2) (Figure 3)
(Drawing)
BLACK
BLACK
WHITEWHITE
BLACK
POWER
SUPPLY
Wire from
Supply
LAMP SOCKET
Ground Copper
Wire in Junction
Box
THERMAL
PROTECTOR
120V AC
CAUTION: RISK OF FIRE OR ELECTRICAL SHOCK CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING
WARNING: FOR YOUR SAFETY READ AND UNDERSTAND INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION. BEFORE WIRING TO POWER SUPPLY, TURN OFF ELECTRICITY AT THE FUSE OR CIRCUIT BREAKER BOX.
CAUTION: TO ENSURE SAFE AND RELIABLE INSTALLATION, VERIFY THAT FIXTURE CORRESPONDS TO PROPER CEILING TYPE/INSTALLATION.
NOTE: PATRIOT RECESSED FIXTURES ARE DESIGNED TO MEET THE LATEST NEC AND UL REQUIREMENTS. BEFORE ATTEMPTING INSTALLATION OF ANY RECESSED LIGHTING FIXTURE, CHECK YOUR LOCAL ELECTRICAL CODE.
THIS CODE SETS THE WIRING STANDARDS FOR YOUR LOCALITY AND SHOULD BE CAREFULLY STUDIED BEFORE STARTING WORK.
Ground Green
DISCLAIMER: These instructions do not claim to cover all details
or variations in the equipment, procedure, or process described, nor
to provide directions for meeting every possible contingency during
installation, operation or maintenance. When additional information is
desired to satisfy a problem not covered suciently for user’s purpose,
please contact a qualied electrician.