Installation Instructions

Ceiling
4. Connect the ground wire (bare copper
or green) from your fixture to the ground
wire (bare copper or green) or ground screw
in the electrical outlet box. Connect the
black wire from the fixture to the black wire
from the electrical box. Connect the white
wire from the fixture to the white wire from
the electrical box.
5. Once connections of wires are
completed, carefully tuck wires and wire
nuts into the electrical box making sure
no bare wire (on the black and white) is
visible at the wire nuts (AA). Install the
bushing (BB) as shown to the knockout
to protect the wires.
White wire
Black wire
House
supply
Ground
wire
4 5
CARE AND MAINTENANCE
TROUBLESHOOTING
1) The light does not come on at all:
a) Make sure the wall switch and circuit breaker are on.
b) Make sure the wiring is correct.
2) Fuse blows or circuit trips when light is turned on.
a) Check for crossed wires, ensure wiring is correct.
If unable to fix any of the above issues, please consult a certified electrician.
Questions, problems, missing parts?
Before returning to your retailer, call our customer service
at 1-800-267-4427 Monday – Friday 8:00 a.m. – 5:00 p.m. EST
5-YEAR LIMITED WARRANTY: If, during normal use, this PATRIOT LIGHTING
®
light fixture fails due to a defect in material and workmanship within five (5) years
from the date of purchase, simply bring this light fixture with your original sales
receipt back to your nearest MENARDS
®
retail store. At its discretion, PATRIOT
LIGHTING
®
agrees to have the lighting fixture replaced with the same or similar
PATRIOT LIGHTING
®
product free of charge, within the stated warranty period,
when returned by the original purchaser with original sales receipt. This warranty:
(1) excludes expendable parts including but not limited to light bulbs; (2) does not
cover damage that has resulted from abuse or misuse; and (3) does not cover any
losses, labor, injuries to persons/property or costs. This warranty does give you
specific legal rights and you may have other rights, which vary from state to state.
ASSEMBLY INSTRUCTIONS (continued)
B
B
AA
To clean, turn off and wipe with a damp, non-abrasive cloth.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage
to the finish.
B
6. Alternatively, if an electrical box is not
available, if the fixture doesn’t cover the
electrical box entirely, please consult a
qualified electrician for Armour Cable or
Conduit Electrical Feed type of installation.
8. Replace the lens by reversing the process
of Step #1.
7. Use the slide switch to choose a color
temperature. The options are Soft White (SW),
Bright White (BW), and Daylight (DL).
Switch
Soft White
3000K
Bright White
4000K
Daylight
5000K
dimmable
These LED lights are dimmable:
SKU#
MAX rated
wattage
Suitable
dimmer
348-1417
45W 80W
This LED light is suitable to be
dimmed by:
Leviton# 742-6672-HLW,
722-6674-PDW MAX 150 W,
Lutron # SCL-153PH-WH,
DVWCL-153PH-WH,
TGCL-153PH-WH MAX 150 W,
Eaton # SAL06P-W-K MAX 150 W.
348-1416
Electrical box
BB
Ceiling
Electrical box
BB
Fixture
Ground
wire