Installation Instructions

9
8
Fig. 12
Fig. 13
Connect the supply leads from the electrical
box to the fixture wire leads using the
pre-installed push-in connectors as per the
illustration (Fig. 12). Insert the black supply
lead into the open hole in the push-in
connector with the black fixture wires
already inserted into it (Fig. 13). Insert the
white supply lead into the open hole in the
push-in connector with the white fixture wires already inserted into it. All wire
connections should be made on the backside of the fixture. Carefully push the
excess wires back inside the electrical box.
Fig. 14
1
Fig. 15
1
Fig. 16
2
2
Position the fixture pan over the long machine
screws attached to the mounting bracket, insert
the screwheads into the keyhole slots by engaging
the straight keyhole slot over the first
screwhead. Use this as a pivot point and maneuver
the curved keyhole slot over the second
screwhead (Fig. 14). Maneuver the fixture until both
screwheads are engaged in the narrow channels
of both keyhole slots. Once the mounting screws
are engaged, maneuver the fixture until the desired
positioning of the fixture has been achieved
(Fig. 15). Fully tighten the mounting screws (Fig. 16).
NOTE: Fixture MUST be properly secured to the
electrical box first. The primary fixture support is
ALWAYS the electrical box.
1
2
*Actual fixture and hardware may differ from the illustrations.
Hardware Kit*
Fixture*
Fixture Installation
Fixture Installation
10
If extra support is needed use the included drywall
anchors. Position the fixture over the electrical box
and locate the circular openings near each end of
the fixture. Mark their position on the mounting
surface (Fig. 17).
Fig. 17
11
Diffuser
Diffuser
Fig. 19
Fixture pan
Locking tabs
Push-in
connectors
Drywall anchor
Support chain
Mounting bracket
Push-in
connectors
Fixture pan
Locking tabs
Support chain slot
Warnings and Cautions
WARNING
Shut off power at the circuit breaker or fuse panel before removing the old fixture
or installing the new one.
LEDs can be damaged by electrostatic discharge (ESD) shock. Before
installation, discharge yourself by touching a grounded bare metal
surface to remove this hazard.
CAUTION
This device complies with Part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Disconnect power to the electrical box and remove the old fixture. If more than two
wire leads are present, keep track of which wires were connected together.
6
7
Using the support chain, connect one end to the back
of the fixture pan near the center in the specially
designed slots (Fig. 9) Hook the other end of the
support chain to the electrical box (Fig. 10). This
will allow for a hands free support for wiring.
Fig. 11
For safety and proper operation, the fixture must be
properly grounded. A green or bare copper ground
wire is preattached to the fixture pan. The fixture
ground wire must be spliced to the green or bare
copper ground wire in the electrical box using
one of the wire nuts (Fig. 11). If house wiring does
not include a ground wire, consult local electrical
code for approved grounding methods.
Fig. 9
Fig. 8
4
3
2
5
Prepare the mounting bracket by attaching both long
machine screws into two opposite round threaded
holes on the mounting bracket (Fig. 3). If the mounting
bracket has more than 2
threaded holes, measure the
distance between the keyhole
slots in the fixture pan (Fig. 4)
and match them up to the corresponding threaded
holes in the mounting bracket. Attach the screws to
the mounting bracket until they are against the mounting bracket.
If the keyhole slots are not punched through, remove
the appropriate knockouts from the back side of the
fixture pan that correspond to the positions of the
mounting screw heads on the mounting bracket (Fig. 8).
This can be done using a flathead screwdriver and
pliers.
Unscrew both long machine screws until the heads of
the screws extend about a 3/8 in. below the ceiling
surface (Fig. 7). NOTE: For proper installation, the
machine screws should be perpendicular to the floor.
Remove the existing screws from the electrical box. Pull
the supply wires from the electrical box through the
center hole of the mounting bracket. Attach the
mounting bracket to the electrical box, using the
electrical box screws removed earlier. Both long
machine screws installed in Step 1 should be installed
with both screwheads facing toward the floor (Fig. 5). If
the fixture needs to be parallel to a specific wall, align
the mounting bracket screwheads to run parallel
through the center run of the
fixture (Fig. 6).
Fig. 3
Fig. 7
Fig. 5
Fig. 6
Fig. 5
1
2
Fig. 4
Fig. 10
13
Insert the diffuser into the fixture pan (Fig. 21).
While holding on to the diffuser, rotate all
locking tabs counter-clockwise to lock
the diffuser in place (Fig. 22).
Fig. 21
Fig. 22
1
Rotate all locking tabs clockwise to unlock the
diffuser from the fixture pan (Fig. 1). Carefully
remove the diffuser (Fig. 2).
12
Fig. 18
Fig. 20
CEILING JOIST MOUNTING: While holding the
fixture in line with the pilot holes, screw the wood
screws into the wooden studs (Fig. 18). Tighten
until the fixture has been secured to the mounting
surface.
DRYWALL MOUNTING: Drill A 3/16-in. pilot hole into
the drywall (Fig. 19). Insert, and then screw the
drywall anchors all the way into the pilot holes. Tap
the drywall anchor head with a hammer, until it is
flush with the mounting surface. Hold the fixture in
line with the drywall anchors that were installed
and drive the wood screws into the drywall anchors
(Fig. 20). Tighten until the fixture has been secured
to the mounting surface.
IMPORTANT: This light fixture uses light emitting diodes (LEDs) to provide
light. LEDs do not have a filament to burn out like a traditional light bulb.
LEDs gradually emit less light over their lifetime, but will typically last 36,000
hours in a residential environment.
Periodically clean the fixture and diffuser using a mild, non-abrasive cleaner
and soft cloth. When cleaning the fixture, make sure the power is turned off.
Do not spray cleaner directly onto any part of the fixture or LEDs.
Care and Maintenance
Minor problems often can be fixed without the help of an electrician. Before doing any work
on the fixture, shut off power supply at the circuit breaker panel to avoid electrical shock.
Problem Cause Solution
Fixture doesn’t light. Power is off. Check if power supply is on.
Bad connection. Check cords and/or wiring.
Bad switch. Test or replace switch.
Fuse blows or circuit breaker Discontinue use. Call customer service.
trips when light is turned on.
Troubleshooting Guide
Important Safety Instructions
Fixture Callouts
WARNING: To reduce the risk of FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS:
1. For INDOOR USE ONLY.
2. Do NOT touch LEDs.
3. Do NOT look directly at lighted LEDs for any length of time.
4. Do NOT touch, operate, or install fixture while in contact with water.
5. Not intended for illumination of aquariums.
6. For electrical requirements, see back of the fixture. Minimum 90° supply
conductors.
7. Do not leave bare wires exposed outside of the electrical box.
SAVE THESE INSTRUCTIONS IN A LOCATION CLOSE TO THE FIXTURE TO
REFER TO THEM AT A LATER TIME.
THIS FIXTURE IS DIMMABLE BY SPECIFIC FORWARD PHASE ELECTRONIC (TRAIC)
DIMMERS AND IS NOT COMPATIBLE WITH 0-10V DIMMING SYSTEMS. Dimmers
tested to be compatible with this fixture are the Lutron: Diva® C•L™: DVWCL-153PH,
Lumea® C•L™: LGCL-153PLH, and Toggler® C•L™: TGCL-153PH. (This list of dimmers
does not imply any guarantee or warranty of compatibility with a particular
application. Dimmers not listed do not imply non-compatibility.)
Dimmer Instructions
Center run of the fixture
Questions? Call our Customer Service Center 1-800-291-8838 or visit www.goodearthlighting.com/support.
To Begin
Arched Door Flush Mount Linear LED Ceiling Fixtures
ITEMS REQUIRED
Installation Time: 45 Minutes.
WARNING: Review important safety instructions before
installation. Check to make sure you have the following:
Flathead
Screwdriver
Phillips
Screwdriver
Pliers Wire Cutters
Electrical Tape Safety Glasses
Wire Strippers
Step Ladder
Item #: 348-3651
48” Linear Ceiling Fixture
Model #LF1057-WH1-48LF5-T
Item #: 348-3650
24” Linear Ceiling Fixture
Model #LF1057-WH1-24LF1-T
Item #: 348-3651
Item #: 348-3651
Item #: 348-3650
Item #: 348-3650
Need Help?
If you have questions regarding installation please call the
Customer Care Center 1-800-291-8838 or visit www.goodearthlighting.com/support.
Patriot Lighting
®
Warranty
© 2016 Good Earth Lighting
1816INS1057-24-48
Printed in China
Distributed by:
Good Earth Lighting
1400 East Business Center Drive, Ste. 108
Mount Prospect, IL 60056
FIVE-YEAR LIMITED WARRANTY: If, during normal use, this
PATRIOT LIGHTING® light breaks or fails due to a defect in
material or workmanship within five (5) years from the date of
original purchase, simply bring this light with the original sales
receipt back to your nearest MENARDS® retail store. At its
discretion, PATRIOT LIGHTING® agrees to have the light or any
defective part(s) repaired or replaced with the same or similar
PATRIOT LIGHTING® product or part free of charge, within the
stated warranty period, when returned by the original purchaser
with the original sales receipt. This warranty; (1) excludes
expendable parts; (2) shall be void if this fixture is used for
commercial and/or retail purposes; and (3) does not cover any
losses, injuries to persons/property or costs. This warranty does
give you specific legal rights and you may have other rights,
which vary from state to state.
Parts List
Keep this guide handy for ordering replacement parts.
Hardware kit
ZH-LF1057F24-WH1
ZH-LF1057F48-WH1
Diffuser
ZD-LF1057L48-WHS
Diffuser
ZD-LF1057L24-WHS
Fig. 1
Fig. 2