Installation Instructions

2
3
ASSEMBLY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
PREPARATION
Please read and understand this entire manual before attempting to assemble,
operate or install the product.
Please save this instruction manual.
WARNING
• Turn off electricity at main fuse box (or circuit breaker box) before beginning
installation by removing fuse (or switching off circuit breaker).
• Be careful not to damage or cut the wire insulation (covering) during fixture
installation. Do not permit wires to contact any surface having a sharp edge.
To do so may damage or cut the wire insulation, which could cause serious
injury or death from electric shock.
This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and operation of the product and
the hazards involved.
CAUTION
All electrical connections must be in agreement with local codes, ordinances or
the national electric code (NEC). Contact your municipal building department to
learn about your local codes, permits and/or inspections.
• Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC.
Consult a qualified electrician before installation.
• Do not connect this fixture to an electrical system that does not provide a means for
equipment grounding. Never use a fixture in a two-wire system that is not grounded.
If you are not sure your lighting system has a grounding means, do not attempt to
install this fixture. Contact a qualified, licensed electrician for information with regards
to proper grounding methods as required by the local electrical code in your area.
• If a dimmer control switch is used with this fixture, obtain professional advice to
determine the correct type and electrical rating required.
Before beginning assembly, installation or operation of product, make sure all parts
are present. Compare parts with package contents list and diagram on previous page.
If any part is missing or damaged, do not attempt to assemble, install or operate the
product. Contact customer service for replacement parts.
Tools Required for Assembly (not included): Slotted Screwdriver, Phillips Screwdriver,
Pliers, Electrical Tape, Wire Cutters, Safety Glasses, Ladder, Wire Stripper
A
4. Once connections of wires are completed,
carefully tuck wires and wire nuts (AA) into
the electrical box making sure no bare wire
(on the black and white) is visible at the
wire nuts (AA). Position fixture (A) over
nipple on mounting bracket (BB) assembly.
Secure fixture (A) in place with star
washer (DD) and cap nut (EE).
2. Option 1: Strip 7mm from each of 3 electrical
wires in electrical box, insert bare wire into easy
connect inserts, Black (live), White (neutral) and
Green/bare copper (ground), as shown below.
Connect (push) electrical wires from electrical
box (house wiring) into correct inserts.
3. Connect (push) electrical wires from
fixture (A) into correct inserts.
Black (live), White (neutral), Green (ground)
5. Remove spinner nut (FF) from socket.
Position glass (B) on lamp and secure with
spinner nut (FF).
6. Install specified bulb type and wattage
(not included).
DD
EE
Nipple
FF
A
B
Bulb
AA
Option 2: For multiple green (ground),
black (live) and white (neutral) wires joined in
the electrical box (house wiring), attach a single
“green” (II), “black” (HH) and “white” (GG) jumper
wire before connecting. Strip 7mm from a 6’’
jumper wires supplied. Then connect (push)
wires into the correct inserts.
GG
II
Green
(Ground)
HH
(L)
Black (Live)
(N)
White
(Neutral)
L
N
Electrical
Box
CC
BB
(L)
Black (Live)
(N)
White
(Neutral)
Green
(Ground)
L
N
Hex nut
Nipple
Green
(Ground)
(L)
Black (Live)
(N)
White
(Neutral)
L
N
Green (Ground)
A
(L)
Black (Live)
(N)
White
(Neutral)
L
N
1. Attach the Easy Connect™ mounting bracket
(BB) to the electrical box using electrical box
screws (CC). Attach the nipple to the Easy
Connect™ mounting bracket (BB) and adjust until
it will clear the canopy when assembled. Lock the
nipple in the correct position using the hex nut.