Installation Instructions
Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
● Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or
switching off circuit breaker).
● Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to contact
any surface having a sharp edge. To do so may damage or cut the wire insulation, which could cause serious injury
or death from electric shock.
CAUTION
● All electrical connections must be in agreement with local codes, ordinances or the national electric code (NEC).
Contact your municipal building department to learn about your local codes, permits and/or inspections.
● Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC. Consult a qualified electrician
before installation.
● Do not connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use
a fixture in a two-wire system that is not grounded. If you are not sure your lighting system has a grounding means,
do not attempt to install this fixture. Contact a qualified, licensed electrician for information with regards to proper
grounding methods as required by the local electrical code in your area.
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble,
install or operate the product. Contact customer service for replacement parts.
Tools Required for Assembly (not included): Slotted Screwdriver, Phillips Screwdriver, Pliers, Electrical Tape, Wire
Cutters, Safety Glasses, Ladder, Wire Stripper.
Pag
201218
e 2 of 4
ASSEMBLY
INSTRUCTIONS
PREPARATION
Turn off the power at fuse or circuit box.
SAFETY INFORMATION
1. Attach the mounting bracket to the
ceiling.
a) If the ceiling material is wood:
Attach the mounting bracket to
the outlet box by using two
mounting screws (BB).
b) If the ceiling material is cement:
Place the mounting bracket to
the outlet box and mark the targets on the ceiling from
the set holes for drilling two holes. Remove the
mounting bracket. Drill the holes and thread the
anchors (DD) into the holes, then attach the mounting
bracket to the outlet box. Finally secure the drywall
screws (AA) through the set holes to the ceiling.
3. - Determine length of chains (GG)
needed to achieve desired fixture
height. (To remove excess chain
section, use pliers to bend link
open.)
Note: Keep the same length for
two chains.
- Weave the fixture wire and
fixture ground wire through one
chain (GG) and the canopy
kit (E).
- Connect one chain (GG) to one
loop and one loop on canopy (E)
using two loop locks (FF).
Repeat it for hanging another chain.
4
CC
E
3
GG
FF
2-a. Attach the trapezoid anchors (B)
to the square rod (F) and thread
the fixture wire and fixture ground
wire through the rods (D) and one
loop.Then secure the rods (D) to
the trapezoid anchors (B).
2-b. Unscrew four set screws from
fixture (A), then attach the
trapezoid anchors (B) to the
fixture (A) and secure it with four
set screws.
BB
AA
DD
1
Set Screw
A
B
D
2-b
F
2-a
B
D
F
4. Pull out the source wires from the
outlet box. Make wire connections
using wire connectors (CC) as
follows:
--- Connect the smooth-coated wire
(marked) from the fixture to the
black wire from the power
source.
--- Connect the ribbed-coated wire
(unmarked) from the fixture to
the white wire from the power
source.
--- Attach the fixture ground wire to
the mounting bracket with the
green ground screw, then
connect it to the house ground
wire with a wire connector (CC).
Carefully put the wires back into the
outlet box.