Installation Instructions

1
Attach fixture mounting screws (AA) into electrical box and leave extended
about 3/4 in. below the ceiling line.
2
Attach the threaded tube (BB) to the center hole in the pan using the hex
nuts (CC) and lock washer (DD). Ensure 3/8 inches to 1/2 inch of the threaded
tube is protruding on the back surface of the pan in order to allow enough
space for the diffuser, cap, and finial to be attached.
3
4
Locate the keyhole slots on the pan. Position the fixture pan over the
electrical box so that both machine screws protruding from the electrical box
pass through the larger round end of both keyholes in the fixture pan .
Once both screw heads have passed through the keyholes, twist the pan,
until both screws are situated at the narrow ends of the keyholes . Hold
in place and tighten the screws down tightly, without distorting or damaging
the fixture pan.
Fixture must be properly grounded. Connect fixture ground wire to ground
wire in electrical box using wire nut (EE). Ground wires can be either green
or bare copper.
Connect black supply lead to black fixture wire and white supply lead to
white fixture wire using wire nuts (EE). Push excess wire into electrical box.
5
Place the diffuser over the threaded tube, and while holding the diffuser in
place with one hand, place the diffuser cap (FF) over the threaded tube and
secure both with the finial (GG). Restore power to the electrical box.
4
3
EE x3
5
FF x1
GG x1
3/4 in.
19 mm
2
BB x1
CC x2
DD x1
1
AA x2
1 2
1
2
CC
BB
DD
CC
Printed in China
Distributed by: Good Earth Lighting
®
1400 East Business Center Drive, Ste. 108 Mount Prospect, IL 60056
Troubleshooting Guide
Fixture doesn’t light.
Problem
Cause Solution
Fuse blows or circuit breaker trips
when light is turned on.
Power is off.
Bad connection.
Bad switch.
Discontinue use.
Check if power supply is on.
Check cords and/or wiring.
Test or replace switch.
Call
Customer Service Center 1-800-291-8838
Before doing any work on the fixture, shut off power supply at the circuit breaker panel
to avoid electrical shock.
Hardware Kit:
ZH-FL1128D19-BR4 (Bronze)
ZH-FL1128D19-NK7 (Brushed Nickel)
Replacement Diffuser:
ZD-FL1128D19-OPL
Replacement Parts List
SAVE THESE INSTRUCTIONS.
1417INSFL1128