Installation Instructions
4
ASSEMBLY INSTRUCTIONS (continued)
A
7.
8.
Wrap all wire connectors with electrical tape as an extra safety measure.
Carefully arrange excess wiring and wire connectors (EE) within outlet
box.
WARNING: Make sure no bare wire or wire strands are visible after
making connections.
Align holes in canopy (A) with screws (BB) on mounting plate (AA) and
push up. Secure the fixture to ceiling with the two decorative nuts (CC)
previously removed (Step 3, page 3).
Install 10 bulbs (included).
Restore power and test fixture.
CAUTION: When replacing bulbs, please allow bulbs to cool down before
touching them.
9.
Outlet Box
*
EE
AA
CC
BB
EE
EE
6.
Prepare wire by stripping 3/4 inch of insulation from wire ends using wire
strippers (not included).
Make wire connections with wire connectors (EE) provided as follows:
Connect the SMOOTH wire from fixture to BLACK wire from outlet box.
Connect the RIBBED wire from fixture to WHITE wire from outlet box.
Connect YELLOW/GREEN ground wire from fixture to BARE/GREEN
ground wire from outlet box.
Note: If your outlet box wiring does not have a BARE/GREEN ground
wire, the YELLOW/GREEN ground wire from fixture should be attached
to the GREEN SCREW labeled GND on the mounting plate.
Note: Screw wire connectors (EE) on in a clockwise direction.
WARNING: Never connect ground wire to WHITE or BLACK power
supply wires.
EE
YELLOW/GREEN
BLACK
WHITE
BARE/GREEN
EE
RIBBED
SMOOTH