Installation Instructions

Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or
switching off circuit breaker).
Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to contact
any surface having a sharp edge. To do so may damage or cut the wire insulation, which could cause serious injury
or death from electric shock.
CAUTION
All electrical connections must be in agreement with local codes, ordinances or the national electric code (NEC).
Contact your municipal building department to learn about your local codes, permits and/or inspections.
Risk of fire – most dwellings built before 1985 have supply wire rated for 140°F/60ºC. Consult a qualified electrician
before installation.
Do not connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use
a fixture in a two-wire system that is not grounded. If you are not sure your lighting system has a grounding means,
do not attempt to install this fixture. Contact a qualified, licensed electrician for information with regards to proper
grounding methods as required by the local electrical code in your area.
PREPARATION
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with
package contents list and diagram on previous page.
Tools Required for Assembly (not included): Screwdriver, Phillips Screwdriver, Pliers, Electrical Tape, Wire Cutters,
Safety Glasses, Ladder, Wire Stripper.
Page 2 of 3
SAFETY INFORMATION
200310
ASSEMBLY INSTRUCTIONS
1. Attach two long screws (CC) to the
holes on the mounting strap (AA).
Thread them in part way: 2 to 3
turns only.
AA
CC
1
AA
BB
2
2. Attach the mounting strap (AA)
to the outlet box using two
mounting screws (BB).
3
AA
DD
3. Connect the fixture black wire to
house black wire and fixture white
wire to house white wire using wire
connectors (DD) provided.
Connect the copper wire on the
light fixture to the mounting
strap (AA) by securing it with the
preinstalled ground screw, then
connect it to the house ground
wire with wire connector (DD).
Tuck all the wires into outlet box.
4. Attach the ceiling pan (A) to the
mounting strap (AA) by inserting
two long screw (CC) heads into
the key holes and rotate the
ceiling pan (A) until it is locked in
place. Then secure the screws
tightly.
4
Keyhole Slot
CC
A
Turn off the power at fuse or circuit box.