Installation Instructions
2 3
Before beginning assembly, installation, or operation of product, make sure all parts are present.
Compare parts with package and hardware contents list on page 1. If any part is missing or
damaged, do not attempt to assemble, install or operate the product. Contact customer service for
replacement parts.
Tools Required for Assembly (not included): Ladder, safety glasses
Estimated assembly time: 15-20 minutes per xture
SAFETY INFORMATION
PREPARATION
WARNING: These products may represent a possible shock or re hazard if improperly installed
or attached in any way. Products should be installed in accordance with these instructions, current
electrical codes, and/or the current National Electric Code (NEC). Disconnect power to the unit prior
to installation.
WARNING: To reduce risk of re, electric shock, or injury to persons,
• Read all installation instructions before beginning. If you have any doubts about how to install this
lighting xture, or if the xture fails to operate completely, consult a qualied electrician to ensure
correct branch circuit conductor.
• This xture is designed for use in a circuit protected by a fuse or circuit breaker.
• Always be sure that power supply is turned off at fuse box or circuit breaker before installing,
cleaning, or servicing the xture.
• This product must be installed in accordance with the applicable installation code by a person
familiar with the construction and operation of the product and the hazards involved.
• Supply conductors (Power Wires) Connecting the xture must be rated minimum 90°C. If
uncertain, consult an electrician.
• To reduce the risk of re, electric shock or injury to persons, do not make or alter any open holes
in a wiring enclosure nor in any electrical components during kit installation.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other
sharp objects.
• There are no serviceable parts inside the xture.
• Suitable for use in wet locations.
• This xture is rated TYPE NON-IC and is not suitable for direct contact with insulation.
• The installer must determine that supply power is 120V AC 50/60Hz at the luminaire before
installation.
• The National Electric Code (NEC) does not permit cords to be concealed where damage to
the cord’s insulation may go unnoticed. To prevent re damage, do not run cord behind walls,
ceilings, softs, or cabinets where it may be inaccessible for examination. Cords should be visually
examined periodically and immediately replace when any damage is noted.
• Do not cover the xture with any heat insulated materials.
• To avoid electrical shock, do not operate xture with missing or damaged lens.
WARNING: To reduce risk of cuts,
• Some metal parts in the xture may have sharp edged. Wear gloves when handling the part.
SAVE THESE INSTRUCTIONS. For safest operation, read and become familiar with complete
installation instructions prior to use. Pay close attention to this manual and stay within its guidelines
when using this product.
CAUTION:
• All parts must be used as indicated in this manual. Do not substitute any parts, leave parts out,
or use parts that are worn out or broken. Failure to obey this instruction could invalidate the ETL
certication.
• LEDs emit bright light. Avoid looking directly at the light source.
• Accounts for small parts and destroy packing material, as these may be hazardous to children.
INSTALLATION INSTRUCTIONS
WARNING
• Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse (or
switching off circuit breaker).
• Be careful not to damage or cut the wire insulation (covering) during xture installation. Do not permit
power cord or housing to contact any surface having a sharp edge. To do so may damage or cut the wire
insulation, which could cause serious injury or death from electric shock.
• This xture is rated for 120V AC operation and draws 12W per xture. The installer must determine whether
supply power is appropriate prior to installation.
• For installation direct to the ceiling via 4” octagonal junction box, see Steps 1-3. For installation to 4”
recessed housing, see Steps 4-6
Note: Toggle the dip switch on the back of
the disc light (A) to select the correlated color
temperature (CCT) prior to installation.
CCT selectable
by dip switch
2700K 3000K 3500K 4000K 5000K
5 CCT selectable
1. For 4” junction box installation:
Attached the round mounting plate
(F) to the junction box using the two
mounting screws (E)
1
2. Pull out the source wires from the
outlet box. Make wire connections
to xture (A) using wire nuts (D)
as follows: black to black, white
to white, and ground to ground.
Carefully put the wires back into the
outlet box.
3. Align the springs on the back
of the xture with the slots on the
round mounting plate (F). Push the
xture upwards until the springs
engage with the round mounting
plate (F) and the xture is ush with
the ceiling and rmly held in place.
4. For 4” recessed housing
installation: Secure the spring
holders (B) to the round mounting
plate (F) using the spring holder
screws (G). Then, connect the round
mounting plate (F) to the back of the
disc light (A) by snapping into place.
2
3
4
F
F
E
D
A
A
A
F
B
G
5. Connect the E26 base whip (C)
to the xture (A) by making wire
connections using wire nuts (D):
black to black and white to white.
Tuck the ground wire away. Then,
connect the E26 base whip (C) to
the socket inside of the recessed
housing by screwing into the socket.
6. Push the disc light (A) up into the
recessed housing, being sure not to
pinch or nick any of the wires.
5
6
C
A
A